WEB Catalog

Product Information ?  WEB Catalog  ? Temperature Control Equipment  ? Air Temperature Controllers

Air Temperature Controllers

Thermo-dryer with Air Temperature Adjustment Function IDH□

    ?Stable supply of temperature and pressure controlled dry clean air
     Can supply compressed air with the same conditions and quality
     regardless of the season
    ?Application example:
     Supplying compressed air with constant conditions to air bearings
     mounted on a tool
    ?Built-in filter
     Nominal filtration: 0.01 μm (99.9% filtration efficiency)
     Outlet oil mist concentration: Max. 0.01 mg/m3 (ANR)
     Outlet cleanliness: Particles of 0.3 μm or more: 3.5 particles/L (ANR)
     or less
    ?Compatible with power supplies from around the world Single-phase
     100, 200, 230 VAC (50/60 Hz)
SeriesAir flow capacity
L/min(ANR)
Outlet air
temperature
adjustment range
Outlet air set
pressure range
Outlet air
temperature
stability
Cooling
method
Compressor
output
IDH□4100 to 50015 to 30℃0.15 to 0.85 MPa±0.1Heater
operation
PID control
Less than 7.5kw
IDH□6200 to 80015 to 30℃0.15 to 0.85 MPa±0.1Heater
operation
PID control
Less than 7.5kw

Features

Stable supply of temperature and pressure controlled dry clean air!

All-in-One

Compact, Space saving

Convenient Functions

Power failure auto-restart function

Even if operation is stopped by unexpected power failure, once the power supply is recovered, the operation will start automatically.
* If an instantaneous power failure occurs, the operation may restart after a few minutes.



Control temperature failure alarm

If the temperature exceeds the set temperature by an arbitrary amount, an error signal will be generated.
* At shipment, if the control temperature exceeds or goes under the set temperature by ±5oC, an error signal will be generated.



Auto-tuning (A·T) function

The control set values (PID) are automatically set.



Key-lock function

The set value is protected so it will not be changed even if keys are touched by mistake or setting is changed.

Application Examples

Go Top