欧美激情国产精品,国产在AJ精品,亚洲精品不卡AV在线播放,国产99久久久久久免费看

WEB Catalog

Product Information ?  WEB Catalog  ? Temperature Control Equipment  ? Thermo-Chillers (Circulating Fluid Temperature Controllers) Dual Channel Thermo chiller for Lasers

Thermo-Chillers (Circulating Fluid Temperature Controllers) Dual Channel Thermo chiller for Lasers

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL

    ?Temperatures for 2 fluid channel systems can be controlled individually
     by one chiller.
    ?Space saving, Reduced wiring
     Footprint: 22% reduction
     One power supply system for 2 channels
    ?Energy saving
     Power consumption reduced by 30%
    ?Touch panel
    ?Power supply:
     3-phase 200 VAC (50 Hz)
     3-phase 200 to 230 VAC (60 Hz)
     3-phase 380 to 415 VAC (50/60 Hz)
     3-phase 460 to 480 VAC (60 Hz)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL
    Manual
    Series View search result
    HRL100
    HRL200
    HRL300
    HRL400
    View search result
  • Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL
    DoC
    Series View search result
    HRL100
    HRL200
    HRL300
    HRL400
    View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRL100
HRL200
HRL300
HRL400
CH1: 15 to 25℃
CH2: 20 to 40℃
CH1:9 kw, 19 kW,
26 kW, 37kw
CH2: 1.0 kW (Max. 1.5 kW)
CH1: ±0.1
CH2: ±0.5
Air-cooled
refrigeration
Water-cooled
refrigeration
Tap water,
Deionized water

[Low GWP Refrigerant Chiller] Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRLF

    ?Low GWP refrigerant chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?Temperatures for 2 fluid channel systems can be controlled individually
     by one chiller.
    ?Space saving, Reduced wiring
    ?Touch panel
     Numeric keypad inputs
     Notice for alarms and maintenance
     Temperature waveform can be displayed.
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRLF200-A-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 19 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Air-cooled refrigerationTap water,
Deionized water
HRLF200-W-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 21.5 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Water-cooled refrigerationTap water,
Deionized water

Thermo-chiller Compact Dual/Basic Type for Lasers HRLE

    ?The temperatures of 2 fluid channel systems can be controlled individually by 1 chiller.
    ?Space saving, Reduced wiring
     Footprint reduced by 21%
     One power supply system for 2 channels
    ?Energy saving
     Power consumption reduced by 17%
SeriesSet temperature
range
Cooling capacity
(CH1, 2 total)
Temperature
stability
Cooling methodCirculating fluid
HRLE050-ACH1:15 to 25℃
CH2:CH1
temperature
+ 0 to 15℃
4.8kW/5.8k
(50Hz/60Hz)
CH1:±0.1
CH2:±0.5
Air-cooled
refrigeration
Tap water,
Deionized (pure) water
HRLE050-WCH1:15 to 25℃
CH2:CH1
temperature
+ 0 to 15℃
4.8kW/5.8k
(50Hz/60Hz)
CH1:±0.1
CH2:±0.5
Water-cooled
refrigeration
Tap water,
Deionized (pure) water
HRLE090-ACH1:15 to 25℃
CH2:CH1
temperature
+ 0 to 15℃
8.0 kW/9.5 kW
(50 Hz/60 Hz)
CH1: ±0.1
CH2: ±0.5
Air-cooled
refrigeration
Tap water,
Deionized (pure) water
HRLE090-WCH1: 9 kw,19 kW, 26 kW
CH2: 1.0 kW
(Max. 1.5 kW)
9.5 kW/11.0 kW
(50 Hz/60 Hz)
CH1: ±0.1
CH2: ±0.5
Water-cooled
refrigeration
Tap water,
Deionized (pure) water

Go Top