欧美激情国产精品,欧美成人精品第一区二区三区,亚洲精品aa片在线观看国产,人妻色综合

產(chǎn)品目錄

產(chǎn)品信息 ?  產(chǎn)品目錄  ? 傳感器/開關(guān)  ? 電子式壓力開關(guān)/壓力傳感器(傳感器、放大器一體型)

電子式壓力開關(guān)/壓力傳感器(傳感器、放大器一體型)

3色顯示 數(shù)字式位置傳感器 ISA3

    ?工件位置狀態(tài)一目了然。
    ?檢測(cè)面與工件的間隙量更直觀。
    ?設(shè)定簡單:可邊觀察顯示值邊進(jìn)行設(shè)定。
    ?節(jié)能:空氣消耗量削減60%。
    ?耐冷凝水能力提高:10倍以上。
系列額定距離范圍配管規(guī)格
供給側(cè)
配管規(guī)格
檢測(cè)側(cè)
ISA3-F0.01~0.03mmRc, G 1/8φ4, φ6快換接頭, G 1/8
ISA3-G0.02~0.15mmRc, G 1/8φ4, φ6快換接頭, G 1/8
ISA3-H0.05~0.30mmRc, G 1/8φ4, φ6快換接頭, G 1/8

產(chǎn)品特點(diǎn)

■The 2-Screen, 3-Color Digital Display

Check at a glance if the workpiece is placed or not.
The clearance distance between the detection surface and the workpiece can be found intuitively.

■3 Step Setting (Switch Point Change Mode)

A simple operation to enter the switch point value
(point at which the clearance reaches the switch point value)


The sub screen display can be selected from 6 display options

■Improved Environmental Resistance

Easier maintenance

Measures against drainage
Drainage resistance:10 times or more

* Based on the SMC’s specific testing condition (oil proof test).
* Compared with the ISA2.


Withstand pressure expanded
Max.:600 kPa(3 times* compared with the ISA2)

* Compared with the ISA2 with 0.2 MPa pressure gauge.

High pressure flushing is possible.

* The switch output will be OFF during flushing.

■Noise reduction, Energy saving, Measures against clogging
■Compact & Lightweight
■Space-saving & Reduction of Work-Hours (Centralized Lead Wire)
■Keylock Function
■Mounting
■Piping Variations
■Manifold
■Application Examples

Confirmation of the datum level for press fitting of a shaft

Confirmation of close contact with the datum level for machining

Confirmation of close contact with the workpiece for machining

■Main Functions

Display OFF mode

Display OFF mode can be selected. The display can be turned OFF to reduce power consumption.


Display color

The color of the main display can be set to change depending upon the output activity. The display color change makes visual identification of the output ON/OFF easier.


Unit conversion

The pressure unit displayed on the sub screen can be changed.

Security code

By activating the security code, the key lock cannot be released without entering a security code.


Displayed value compensation

The displayed value can be corrected within ±20% R.D. of the displayed value at the time of shipment.


Forced output

The output can be fixed to an on/off state when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output.


Zero-clear of pressure display

The pressure value displayed on the sub screen can be cleared to zero.